Contact Us

Our experienced team can help.

 

Geothermal

Save 30%-70% off your home heating costs by switching to Geothermal Heat

As the prices of oil and natural gas continue to rise homeowners continually find it's more and more expensive to heat their homes. And with rising energy costs it's certainly not cheap to air-condition a house in the summer either.

The Natural Way

Benefits:

  • Lower Operating Costs
    • Up to 60% energy savings vs. traditional systems.
  • Quiet
    • No loud outdoor equipment.
  • Reliable, Long Life
    • Geothermal units are installed indoors vs. outdoors.
  • Environmentally Friendly
    • Rated best clean heating & cooling technology by the EPA. No greenhouse gases emitted.

How They Work

Heating

In the cooling mode, a geothermal system air conditions your home by reversing the heating process. Instead of extracting heat from the ground, it is extracted from your home and either moved back into the earth loop, or used to preheat the water in your hot tank. Once the heat is removed from the air, it is distributed through the duct system in your home.

Cooling

In the cooling mode, a geothermal system air conditions your home by reversing the heating process. Instead of extracting heat from the ground, it is extracted from your home and either moved back into the earth loop, or used to preheat the water in your hot tank. Once the heat is removed from the air, it is distributed through the duct system in your home.

Types

Horizontal Loop

Often used when adequate land surface is available. Depending on system needs and space available, pipes are placed in trenches that range in length from 100 to 400 feet.

Vertical Loops

The ideal choice when available land surface is limited. Drilling equipment is used to bore small-diameter holes from 75 to 300 feet deep.

Pond/Lake Loops

Very economical to install when a large body of water is available. Coils of pipes are simply placed on the bottom of the pond or lake.

Open Loops (Well-Water Systems)

In ideal conditions, an open looped application can be the most economical type of geothermal system. These use groundwater from a well as a direct energy source.


All-In-One Geothermal Product Offering

GC

Infinity® Series Geothermal Heat Pump

View Brochure
Model Family: GC
Closed Loop Cooling Efficiency: Up to 32.0 EER
Closed Loop Heating Efficiency: Up to 4.7 COP
Energy Star Rated: ENERGY STAR®
Refrigerant Type: Puron®
Sound Level: Quiet operation
Blower Motor: Variable-speed blower
Compressor: Two-stage compressor
Factory Warranty Parts: 10 year parts limited warranty 5 year labor limited warranty
Factory Warranty Compressor: 10 year parts limited warranty 5 year labor limited warranty
Manufacturer's Stated Benefits:
  • Open loop cooling: Up to 37.0 EER
  • Open loop heating Up to 5.2 COP
  • Summer dehumidification is compressor and blower motor enhanced
  • Excellent cold weather performance
  • Sound enhancements: Fully insulated cabinet, compressor blanket and double-isolation compressor mounting system
  • Microprocessor control board
  • Recommended control: Infinity control
  • Optimal humidity and temperature control when managed by the Inifinty Touch control
  • Large operating temperature range
  • Corrosion-resistant air coil for long life
  • Stainless steel drain pan
GP

Performance™ Series Geothermal Heat Pump

View Brochure
Model Family: GP
Closed Loop Cooling Efficiency: Up to 24.5 EER
Closed Loop Heating Efficiency: Up to 4.0 COP
Energy Star Rated: ENERGY STAR ®
Refrigerant Type: Puron®
Sound Level: Ultra quiet fan sound levels
Blower Motor: Variable-speed blower motor
Compressor: Two-stage scroll compressor
Factory Warranty Parts: 10-year parts and labor limited warranty upon registration
Factory Warranty Compressor: 10-year parts and labor limited warranty upon registration
Manufacturer's Stated Benefits:
  • Summer dehumidification is compressor and blower motor enhanced
  • Excellent cold weather performance
  • Sound enhancements: Fully insulated cabinet, compressor blanket and double-isolation compressor mounting system
  • Comfort Alert™ compressor diagnostics
  • Microprocessor control board
  • Recommended control: Performance™ Edge® relative humidity thermostat
  • Heavy-duty, galvanized steel cabinet
  • Baked on urethane base coat and polyester top coat paint in taupe metallic
  • Large operating temperature range
  • Corrosion-resistant air coil for long life
  • Stainless steel drain pan
GBA

Comfort Series Water-Air Heat Pump With Puron Advance

View Brochure
Model Family: GBA
Closed Loop Cooling Efficiency: 16.0 - 24.0 EER (Closed Loop)
Closed Loop Heating Efficiency: Up to 4.1 COP (Closed Loop)
Energy Star Rated: Energy Star
Refrigerant Type: Puron Advance refrigerant
Sound Level: Fully insulated cabinet with fiberglass
Blower Motor: ECM constant airflow blower motor
Compressor: Single-stage rotary compressor on 1.5 ton models, two-stage scroll compressor on 2 - 5 ton models.
Factory Warranty Parts: Ten-year parts and five-year labor limited warranty upon timely registration
Factory Warranty Compressor: Ten-year parts and five-year labor limited warranty upon timely registration
Manufacturer's Stated Benefits:
  • Tin plated copper tubing in air coil
  • Unit available in vertical up-flow, and horizontal
  • Enhanced hinged electrical panel for increased component accessibility
  • Units equipped with A2L Dissipation Sensor and dissipation control features.